Per page:   First Prev   1 2 3 4 5 6 7 8 9 10 of  153  Next Last                                    
Object Status Strength Ascending Reference Safety Info
BioKnotless Plus Anchor w/Panacryl
Nonmetallic
Depuy
www.Depuy.com 
 Safe

1,5,3 

  Orthopedic Implants, Materials, and Devices 
Intraocular lens implant
Binkhorst, iridocapsular lense
titanium loop (titanium)
ocular 
 Safe

1.0 

31. Albert DW, Olson KR, Parel JM, et al. Magnetic resonance imaging and retinal tacks. Arch Ophthalmol 1990;108:320-321.  Ocular Implants, Lens Implants, and Devices 
Intraocular lens implant
Worst, platinum clip lense
ocular 
 Safe

1.0 

31. Albert DW, Olson KR, Parel JM, et al. Magnetic resonance imaging and retinal tacks. Arch Ophthalmol 1990;108:320-321.  Ocular Implants, Lens Implants, and Devices 
Intraocular lens implant
Binkhorst, iridocapsular lense
platinum-iridium loop (platinum, iridium)
ocular 
 Safe

1.0 

31. Albert DW, Olson KR, Parel JM, et al. Magnetic resonance imaging and retinal tacks. Arch Ophthalmol 1990;108:320-321.  Ocular Implants, Lens Implants, and Devices 
EXO adjustable coller
halo and cervical fixation
Florida Manufacturing Co.
Daytona, FL 
 Conditional 4

1.0 

15. Clayman DA, Murakami ME, Vines FS. Compatibility of cervical spine braces with MR imaging. A study of nine nonferrous devices. Am J Neuroradiol 1990;11:385-390.  Halo Vests and Cervical Fixation Devices 
Guilford cervical orthosis, modified
halo and cervical fixation
Guilford & Son, Ltd.
Cleveland, OH 
 Safe

1.0 

15. Clayman DA, Murakami ME, Vines FS. Compatibility of cervical spine braces with MR imaging. A study of nine nonferrous devices. Am J Neuroradiol 1990;11:385-390.  Halo Vests and Cervical Fixation Devices 
Guilford cervical orthosis
halo and cervical fixation
Guilford & Son, Ltd.
Cleveland, OH 
 Conditional 4

1.0 

15. Clayman DA, Murakami ME, Vines FS. Compatibility of cervical spine braces with MR imaging. A study of nine nonferrous devices. Am J Neuroradiol 1990;11:385-390.  Halo Vests and Cervical Fixation Devices 
Philadelphia coller
halo and cervical fixation
Philadelphia Coller Co.
Westville, NJ 
 Safe

1.0 

15. Clayman DA, Murakami ME, Vines FS. Compatibility of cervical spine braces with MR imaging. A study of nine nonferrous devices. Am J Neuroradiol 1990;11:385-390.  Halo Vests and Cervical Fixation Devices 
PMT halo cervical orthosis
halo and cervical fixation
PMT Corp.
Chanhassen, MN 
 Safe

1.0 

15. Clayman DA, Murakami ME, Vines FS. Compatibility of cervical spine braces with MR imaging. A study of nine nonferrous devices. Am J Neuroradiol 1990;11:385-390.  Halo Vests and Cervical Fixation Devices 
PMT halo cervical orthosis
with graphite rods and halo ring
halo and cervical fixation
PMT Corp.
Chanhassen, MN 
 Safe

1.0 

15. Clayman DA, Murakami ME, Vines FS. Compatibility of cervical spine braces with MR imaging. A study of nine nonferrous devices. Am J Neuroradiol 1990;11:385-390.  Halo Vests and Cervical Fixation Devices 
S.O.M.I. cervical orthosis
halo and cervical fixation
U.S. Manufacturing Co.
Pasadena, CA 
 Conditional 4

1.0 

15. Clayman DA, Murakami ME, Vines FS. Compatibility of cervical spine braces with MR imaging. A study of nine nonferrous devices. Am J Neuroradiol 1990;11:385-390.  Halo Vests and Cervical Fixation Devices 
Downs Multi-Positional, Aneurysm Clip
(17-7PH) 
 Unsafe 1

1.44 

1. New PFJ, Rosen BR, Brady TJ, et al. Potential hazards and artifacts of ferromagnetic and nonferromagnetic surgical and dental materials and devices in nuclear magnetic resonance imaging. Radiology 1983;147:139-148.  Aneurysm Clips 
Olivercrona, Aneurysm Clip   Safe

1.44 

1. New PFJ, Rosen BR, Brady TJ, et al. Potential hazards and artifacts of ferromagnetic and nonferromagnetic surgical and dental materials and devices in nuclear magnetic resonance imaging. Radiology 1983;147:139-148.  Aneurysm Clips 
Kapp, Curved (404 SS), Aneurysm Clip
V. Mueller 
 Unsafe 1

1.44 

1. New PFJ, Rosen BR, Brady TJ, et al. Potential hazards and artifacts of ferromagnetic and nonferromagnetic surgical and dental materials and devices in nuclear magnetic resonance imaging. Radiology 1983;147:139-148.  Aneurysm Clips 
Kapp, Straight (404 SS), Aneurysm Clip
V. Mueller 
 Unsafe 1

1.44 

1. New PFJ, Rosen BR, Brady TJ, et al. Potential hazards and artifacts of ferromagnetic and nonferromagnetic surgical and dental materials and devices in nuclear magnetic resonance imaging. Radiology 1983;147:139-148.  Aneurysm Clips 
Drake (DR 14, DR 21), Aneurysm Clip
Edward Weck, Triangle Park, NJ 
 Unsafe 1

1.44 

1. New PFJ, Rosen BR, Brady TJ, et al. Potential hazards and artifacts of ferromagnetic and nonferromagnetic surgical and dental materials and devices in nuclear magnetic resonance imaging. Radiology 1983;147:139-148.  Aneurysm Clips 
Dynalink Stent
10-mm x 100-mm
Nickel/Titanium
Guidant Corporation
Santa Clara, CA 
 Safe

1.5 

  Coils, Filters, Stents, and Grafts 
Dynalink Stent
10-mm x 100-mm
Nickel/Titanium
Guidant Corporation
Santa Clara, CA 
 Safe

1.5 

  Coils, Filters, Stents, and Grafts 
Fanelli Laparoscopic Endobiliary Stent
Cook Medical, www.cookmedical.com 
 Safe

1.5 

  Coils, Filters, Stents, and Grafts 
GRAFTcath
316L SS, Titanium, silicone
GRAFTcath, Inc.
Coon Rapids, MN 
 Safe

1.5 

  Coils, Filters, Stents, and Grafts 
SUNDT AVM MICRO CLIP
# 4
MP35N
Codman
Codman & Shurtleff, Inc.
Johnson and Johnson Company
Raynham, MA 
 Safe

1.5 

  Aneurysm Clips 
SUNDT AVM MICRO CLIP
# 5
MP35N
Codman
Codman & Shurtleff, Inc.
Johnson and Johnson Company
Raynham, MA 
 Safe

1.5 

  Aneurysm Clips 
Filshie Clip
Avalon Medical Corporation
Williston, VT 
 Safe

1.5 

  Hemostatic Clips, Other Clips, Fasteners, and Staples 
Double Chamber Breast Tissue Expander
Model 20739-400
SILIMED, Inc.
Dallas, TX 
 Unsafe 1

1.5 

  Breast Tissue Expanders and Implants 
Diverter Stent
8-mm x 32-mm
Elgiloy (Conichrome), Tantalum
MindGuard, Ltd.
Israel 
 Safe

1.5 

  Coils, Filters, Stents, and Grafts 
Dynalink Stent
5-mm x 100-mm
Nickel/Titanium
Guidant Corporation
Santa Clara, CA 
 Safe

1.5 

  Coils, Filters, Stents, and Grafts 
SUNDT SLIM-LINE ANEURYSM CLIP
Fenestrated Straight
4-mm opening, 24-mm blade
MP35N
Codman
Codman & Shurtleff, Inc.
Johnson and Johnson Company
Raynham, MA 
 Safe

1.5 

  Aneurysm Clips 
SLIM-LINE ANEURYSM CLIP
Fenestrated Straight
4-mm opening
6-mm blade
MP35N
Codman
Codman & Shurtleff, Inc.
Johnson and Johnson Company
Raynham, MA 
 Safe

1.5 

  Aneurysm Clips 
SUNDT SLIM-LINE ANEURYSM CLIP
Fenestrated Bayonet
Straight, 6-mm opening
15-mm blade
MP35N
Codman
Codman & Shurtleff, Inc.
Johnson and Johnson Company
Raynham, MA 
 Safe

1.5 

  Aneurysm Clips 
SUNDT SLIM-LINE ANEURYSM CLIP
Sharp Right Angle
12-mm blade
MP35N
Codman
Codman & Shurtleff, Inc.
Johnson and Johnson Company
Raynham, MA 
 Safe

1.5 

  Aneurysm Clips 

_____________________________________________________________________________________
  (c) 2017 by Shellock R & D Services, Inc. and Frank G. Shellock, Ph.D. All Rights Reserved. All copyrights and pertinent trademarks are owned by Shellock R & D Services, Inc. and Frank G. Shellock, Ph.D. No part of the MRISAFETY.COM web site may be reproduced, stored in any retrieval system, or transmitted in any form or by any means, physical, electronic or otherwise, without the prior written permission of Shellock R & D Services, Inc. or Frank G. Shellock, Ph. D. Request for permission to reproduce any information contained on the MRISAFETY.COM web site should be addressed to: frank.shellock@gte.net
Be sure to read our Disclaimer.