Object Status Strength Ascending Reference Safety Info
Neurostimulation System
PrimeAdvanced SureScan MRI, Model 97702
Spinal Cord Stimulation System
Important Note: This device is a “full-body eligible system” if all specific MRI conditions and device requirements are carefully followed. Please refer to the labeling documents available at www.medtronic.com/mri
Medtronic, Inc., www.medtronic.com/mri 
 Conditional 5

 

  Spinal Cord Stimulation, SureScan MRI Version, Medtronic, Inc. 
3M Tegaderm CHG Chlorhexidine Gluconate I.V. Securement Dressing
3M, www.3m.com 
 Safe

 

  Miscellaneous Implants and Devices 
Neurostimulation System
Vercise Deep Brain Stimulation System
DBS System
Boston Scientific, www.bostonscientific.com 
 Unsafe 2

 

  Neurostimulation (Neuromodulation) Systems: General Information 
Perfusafe 2
Vygon, www.vygon.com 
 Conditional 6

 

  Vascular Access Ports, Infusion Pumps*, Catheters, and Accessories 
Cerebral ventricular shunt tube connector (type unknown)
misc. 
 Unsafe 1

0.147 

1. New PFJ, Rosen BR, Brady TJ, et al. Potential hazards and artifacts of ferromagnetic and nonferromagnetic surgical and dental materials and devices in nuclear magnetic resonance imaging. Radiology 1983;147:139-148.  Cerebrospinal Fluid (CSF) Shunt Valves and Accessories 
Drake (DR 16), aneurysm clip
Edward Weck
Triangle Park, NJ 
 Unsafe 1

0.147 

1. New PFJ, Rosen BR, Brady TJ, et al. Potential hazards and artifacts of ferromagnetic and nonferromagnetic surgical and dental materials and devices in nuclear magnetic resonance imaging. Radiology 1983;147:139-148.  Aneurysm Clips 
Housepian, aneurysm clip   Unsafe 1

0.147 

1. New PFJ, Rosen BR, Brady TJ, et al. Potential hazards and artifacts of ferromagnetic and nonferromagnetic surgical and dental materials and devices in nuclear magnetic resonance imaging. Radiology 1983;147:139-148.  Aneurysm Clips 
Stevens (silver alloy)
aneurysm clip 
 Safe

0.15 

6. Barrafato D, Henkelman RM. Magnetic resonance imaging and surgical clips. Can J Surg 1984;27:509-512.  Aneurysm Clips 
MED-EL COMBI 40+ Cochlear Implant System
MED-EL Corporation, www.medel.com 
 Conditional 5

0.2, 1.5 

  Cochlear Implants, MED-EL Corporation 
Pulsar Cochlear Implant
PULSARCI100
MED-EL, www.medel.com/us/isi-cochlear-implant-systems 
 Conditional 5

0.2,1.5 

98. Med-El, www.medel.com www.medel.com/us/isi-cochlear-implant-systems  Cochlear Implants, MED-EL Corporation 
MED-EL CONCERT or CONCERT PIN Cochlear Implant
Med-El, www.medel.com/us/isi-cochlear-implant-systems 
 Conditional 5

0.2,1.5 

98. Med-El, www.medel.com www.medel.com/us/isi-cochlear-implant-systems  Cochlear Implants, MED-EL Corporation 
MED-EL SONATA Cochlear Implant
Med-El,www.medel.com/us/isi-cochlear-implant-systems 
 Conditional 5

0.2,1.5 

98. Med-El, www.medel.com www.medel.com/us/isi-cochlear-implant-systems  Cochlear Implants, MED-EL Corporation 
Cochlear Implant
HiRes 90K Cochlear Implant
Advanced Bionics Corporation
Sylmar, CA 
 Conditional 5

0.3 

  Cochlear Implant, HiRes 90K Cochlear Implant, HiRes 90K ADVANTAGE Cochlear Implant, Advanced Bionics Corporation 
Zielke rod with screw
washer and nut (316L SS)
orthopedic implant 
 Safe

0.3 

33. Lyons CJ, Betz RR, Mesgarzadeh M, et al. The effect of magnetic resonance imaging on metal spine implants. Spine 1989;14:670-672.  Orthopedic Implants, Materials, and Devices 
Cervical wire, 18 gauge (316L SS)
orthopedic implant 
 Safe

0.3 

33. Lyons CJ, Betz RR, Mesgarzadeh M, et al. The effect of magnetic resonance imaging on metal spine implants. Spine 1989;14:670-672.  Orthopedic Implants, Materials, and Devices 
Charnley-Muller hip prosthesis
(Protasyl-10 alloy)
orthopedic implant 
 Safe

0.3 

  Orthopedic Implants, Materials, and Devices 
Cotrel rods
with hooks (316L SS)
orthopedic implant 
 Safe

0.3 

33. Lyons CJ, Betz RR, Mesgarzadeh M, et al. The effect of magnetic resonance imaging on metal spine implants. Spine 1989;14:670-672.  Orthopedic Implants, Materials, and Devices 
Drummond wire (316L SS)
orthopedic implant 
 Safe

0.3 

33. Lyons CJ, Betz RR, Mesgarzadeh M, et al. The effect of magnetic resonance imaging on metal spine implants. Spine 1989;14:670-672.  Orthopedic Implants, Materials, and Devices 
DTT, device
for transverse traction (316L SS)
orthopedic implant 
 Safe

0.3 

33. Lyons CJ, Betz RR, Mesgarzadeh M, et al. The effect of magnetic resonance imaging on metal spine implants. Spine 1989;14:670-672.  Orthopedic Implants, Materials, and Devices 
Harrington distraction rod with hooks (316L SS)
orthopedic implant 
 Safe

0.3 

33. Lyons CJ, Betz RR, Mesgarzadeh M, et al. The effect of magnetic resonance imaging on metal spine implants. Spine 1989;14:670-672.  Orthopedic Implants, Materials, and Devices 
Luque Wire
orthopedic implant 
 Safe

0.3 

33. Lyons CJ, Betz RR, Mesgarzadeh M, et al. The effect of magnetic resonance imaging on metal spine implants. Spine 1989;14:670-672.  Orthopedic Implants, Materials, and Devices 
EEG electrodes, Adult E-6-GH (gold plated silver)
misc.
Grass Co.
Quincy, MA 
 Safe

0.3 

51. Lufkin R, Jordan S, Lylcyk M. MR imaging with topographic EEG electrodes in place. Am J Neuroradiol 1988;9:953-954.  Miscellaneous Implants and Devices 
EEG electrodes, Pediatric E-5-GH (gold plated silver)
misc.
Grass Co.
Quincy, MA 
 Safe

0.3 

51. Lufkin R, Jordan S, Lylcyk M. MR imaging with topographic EEG electrodes in place. Am J Neuroradiol 1988;9:953-954.  Miscellaneous Implants and Devices 
House wire (SS)
otologic implant
Otomed 
 Safe

0.5 

39. White DW. Interaction between magnetic fields and metallic ossicular prostheses. Am J Otol 1987;8:290-292.  Otologic Implants 
House wire (tantalum)
otologic implant
Otomed 
 Safe

0.5 

39. White DW. Interaction between magnetic fields and metallic ossicular prostheses. Am J Otol 1987;8:290-292.  Otologic Implants 
Richards Shepherd's crook (platinum)
otologic implant
Richards Medical Co.
Memphis, TN 
 Safe

0.5 

39. White DW. Interaction between magnetic fields and metallic ossicular prostheses. Am J Otol 1987;8:290-292.  Otologic Implants 
House-type incus prosthesis
otologic implant 
 Safe

0.6 

  Otologic Implants 
Cochlear implant
otologic implant
3M/House 
 Unsafe 1

0.6 

37. Mattucci KF, Setzen M, Hyman R, et al. The effect of nuclear magnetic resonance imaging on metallic middle ear protheses. Otolaryngol Head Neck Surg 1986;94:441-443.  Otologic Implants 
Cochlear implant
otologic implant
3M/Vienna 
 Unsafe 1

0.6 

37. Mattucci KF, Setzen M, Hyman R, et al. The effect of nuclear magnetic resonance imaging on metallic middle ear protheses. Otolaryngol Head Neck Surg 1986;94:441-443.  Otologic Implants 
Cody tack
otologic implant 
 Safe

0.6 

37. Mattucci KF, Setzen M, Hyman R, et al. The effect of nuclear magnetic resonance imaging on metallic middle ear protheses. Otolaryngol Head Neck Surg 1986;94:441-443.  Otologic Implants 

_____________________________________________________________________________________
  (c) 2017 by Shellock R & D Services, Inc. and Frank G. Shellock, Ph.D. All Rights Reserved. All copyrights and pertinent trademarks are owned by Shellock R & D Services, Inc. and Frank G. Shellock, Ph.D. No part of the MRISAFETY.COM web site may be reproduced, stored in any retrieval system, or transmitted in any form or by any means, physical, electronic or otherwise, without the prior written permission of Shellock R & D Services, Inc. or Frank G. Shellock, Ph. D. Request for permission to reproduce any information contained on the MRISAFETY.COM web site should be addressed to: frank.shellock@gte.net
Be sure to read our Disclaimer.