Search THE LIST.   All parameters below are optional.  Click Search button.



     ALL (default) means search results will contain *ALL* words you type above.
                       Selecting ANY returns records having *ANY* words above. (more recs returned) 
   Result Status
Clear Search Fields Click Here for the Info and Terminology Page Regarding THE LIST    
Records: 4581                              Click Here for Search HELP  
Per page:   First Prev   4 5 6 7 8 9 10 11 12 13 of  153  Next Last                                    
Object Status Ascending Strength Reference Safety Info
Cody tack
otologic implant 
 Safe

0.6 

37. Mattucci KF, Setzen M, Hyman R, et al. The effect of nuclear magnetic resonance imaging on metallic middle ear protheses. Otolaryngol Head Neck Surg 1986;94:441-443.  Otologic Implants 
Ehmke hook stapes prosthesis (platinum)
otologic implant
Richards Medical Co.
Memphis, TN 
 Safe

1.5 

35. Shellock FG, Schatz CJ. High-field strength MR imaging and metallic otologic implants. Am J Neuroradiol 1991;12:279-281.  Otologic Implants 
Fisch piston (Teflon, SS)
otologic implant
Richards Medical Co.
Memphis, TN 
 Safe

1.5 

38. Applebaum EL, Valvassori GE. Further studies on the effects of magnetic resonance fields on middle ear implants. Ann Otol Rhinol Laryngol 1990;99:801-804.  Otologic Implants 
Flex H/A notched
offset total ossicular prosthesis (316L SS)
otologic implant
Microtek Medical, Inc.
Memphis, TN 
 Safe

1.5 

36. Nogueira M, Shellock FG. Otologic bioimplants: ex vivo assessment of ferromagnetism and artifacts at 1.5 Tesla. Am J Roentgenol 1995;163:1472-1473.  Otologic Implants 
Flex H/A offset partial ossicular prosthesis (316L SS)
Microtek Medical, Inc.
Memphis, TN 
 Safe

1.5 

36. Nogueira M, Shellock FG. Otologic bioimplants: ex vivo assessment of ferromagnetism and artifacts at 1.5 Tesla. Am J Roentgenol 1995;163:1472-1473.  Otologic Implants 
House double loop (ASTM-318- 76 Grade 2 SS)
otologic implant
Storz
St. Louis, MO 
 Safe

1.5 

35. Shellock FG, Schatz CJ. High-field strength MR imaging and metallic otologic implants. Am J Neuroradiol 1991;12:279-281.  Otologic Implants 
House double loop (tantalum)
otologic implant
Storz
St. Louis, MO 
 Safe

1.5 

35. Shellock FG, Schatz CJ. High-field strength MR imaging and metallic otologic implants. Am J Neuroradiol 1991;12:279-281.  Otologic Implants 
House single loop (ASTM-318- 76, Grade 2 SS)
otologic implant
Storz
St. Louis, MO 
 Safe

1.5 

31. Albert DW, Olson KR, Parel JM, et al. Magnetic resonance imaging and retinal tacks. Arch Ophthalmol 1990;108:320-321.  Otologic Implants 
House single loop (tantalum)
otologic implant
Storz
St. Louis, MO 
 Safe

1.5 

35. Shellock FG, Schatz CJ. High-field strength MR imaging and metallic otologic implants. Am J Neuroradiol 1991;12:279-281.  Otologic Implants 
House wire (SS)
otologic implant
Otomed 
 Safe

0.5 

39. White DW. Interaction between magnetic fields and metallic ossicular prostheses. Am J Otol 1987;8:290-292.  Otologic Implants 
House wire (tantalum)
otologic implant
Otomed 
 Safe

0.5 

39. White DW. Interaction between magnetic fields and metallic ossicular prostheses. Am J Otol 1987;8:290-292.  Otologic Implants 
House-type incus prosthesis
otologic implant 
 Safe

0.6 

  Otologic Implants 
House-type stainless steel
piston and wire (ASTM-318-76 Grade 2 SS)
otologic implant
Xomed-Treace Inc.
A Bristol-Myers Squibb Co. 
 Safe

1.5 

35. Shellock FG, Schatz CJ. High-field strength MR imaging and metallic otologic implants. Am J Neuroradiol 1991;12:279-281.  Otologic Implants 
House-type wire loop stapes prosthesis (316L SS)
otologic implant
Richards Medical Co.
Memphis, TN 
 Safe

1.5 

35. Shellock FG, Schatz CJ. High-field strength MR imaging and metallic otologic implants. Am J Neuroradiol 1991;12:279-281.  Otologic Implants 
McGee piston stapes prosthesis (316L, SS)
otologic implant
Richards Medical Co.
Memphis, TN 
 Safe

1.5 

35. Shellock FG, Schatz CJ. High-field strength MR imaging and metallic otologic implants. Am J Neuroradiol 1991;12:279-281.  Otologic Implants 
McGee piston stapes prosthesis (platinum, 316L SS)
otologic implant
Richards Medical Co.
Memphis, TN 
 Safe

1.5 

35. Shellock FG, Schatz CJ. High-field strength MR imaging and metallic otologic implants. Am J Neuroradiol 1991;12:279-281.  Otologic Implants 
Tantalum Powder
 
 Safe

1.5 

  Miscellaneous Implants and Devices 
Tweezers, Ceramic (prototype, ceramic)
misc.
MicroSurgical Techniques, Inc.
Fort Collins, CO 
 Safe

1.5 

48. Shellock FG, Shellock VJ. Evaluation of MR compatibility of 38 bioimplants and devices. Radiology 1995;197:174.  Surgical Instruments and Devices 
UroLume Endoprosthesis
misc.
American Medical Systems
Minnetonka, MN 
 Safe

1.5 

  Miscellaneous Implants and Devices 
Retinal tack (titanium alloy)
ocular
Coopervision
Irvine, CA 
 Safe

1.5 

32. Joondeph BC, Peyman GA, Mafee MF, et al. Magnetic resonance imaging and retinal tacks [Letter]. Arch Ophthalmol 1987;105:1479-1480.  Ocular Implants, Lens Implants, and Devices 
Retinal tack, Norton staple (platinum, rhodium)
ocular
Norton 
 Safe

1.5 

32. Joondeph BC, Peyman GA, Mafee MF, et al. Magnetic resonance imaging and retinal tacks [Letter]. Arch Ophthalmol 1987;105:1479-1480.  Ocular Implants, Lens Implants, and Devices 
Single tantalum clip (tantalum)
ocular 
 Safe

1.5 

29. Shellock FG, Myers SM, Schatz CJ. Ex vivo evaluation of ferromagnetism determined for metallic scleral "buckles" exposed to a 1.5 T MR scanner. Radiology 1992;185:288-289.  Ocular Implants, Lens Implants, and Devices 
Bullet, .357 inch (aluminum, lead)
pellets and bullets
Winchester 
 Safe

1.5 

42. Teitelbaum GP, Yee CA, Van Horn DD, et al. Metallic ballistic fragments: MR imaging safety and artifacts. Radiology 1990;175:855-859.  Pellets, Bullets, and Shrapnel 
Bullet, .357 inch (bronze, plastic)
pellets and bullets
Patton-Morgan 
 Safe

1.5 

42. Teitelbaum GP, Yee CA, Van Horn DD, et al. Metallic ballistic fragments: MR imaging safety and artifacts. Radiology 1990;175:855-859.  Pellets, Bullets, and Shrapnel 
Bullet, .357 inch (copper, lead)
pellets and bullets
Cascade 
 Safe

1.5 

42. Teitelbaum GP, Yee CA, Van Horn DD, et al. Metallic ballistic fragments: MR imaging safety and artifacts. Radiology 1990;175:855-859.  Pellets, Bullets, and Shrapnel 
Bullet, .357 inch (copper, lead)
pellets and bullets
Hornady 
 Safe

1.5 

42. Teitelbaum GP, Yee CA, Van Horn DD, et al. Metallic ballistic fragments: MR imaging safety and artifacts. Radiology 1990;175:855-859.  Pellets, Bullets, and Shrapnel 
Bullet, .357 inch (copper, lead)
pellets and bullets
Patton-Morgan 
 Safe

1.5 

42. Teitelbaum GP, Yee CA, Van Horn DD, et al. Metallic ballistic fragments: MR imaging safety and artifacts. Radiology 1990;175:855-859.  Pellets, Bullets, and Shrapnel 
Bullet, .357 inch (lead)
pellets and bullets
Remington 
 Safe

1.5 

42. Teitelbaum GP, Yee CA, Van Horn DD, et al. Metallic ballistic fragments: MR imaging safety and artifacts. Radiology 1990;175:855-859.  Pellets, Bullets, and Shrapnel 
Bullet, .357 inch (nickel, copper, lead)
pellets and bullets
Winchester 
 Safe

1.5 

42. Teitelbaum GP, Yee CA, Van Horn DD, et al. Metallic ballistic fragments: MR imaging safety and artifacts. Radiology 1990;175:855-859.  Pellets, Bullets, and Shrapnel 
Bullet, .357 inch (nylon, lead)
pellets and bullets
Smith & Wesson 
 Safe

1.5 

42. Teitelbaum GP, Yee CA, Van Horn DD, et al. Metallic ballistic fragments: MR imaging safety and artifacts. Radiology 1990;175:855-859.  Pellets, Bullets, and Shrapnel 

_____________________________________________________________________________________
  (c) 2017 by Shellock R & D Services, Inc. and Frank G. Shellock, Ph.D. All Rights Reserved. All copyrights and pertinent trademarks are owned by Shellock R & D Services, Inc. and Frank G. Shellock, Ph.D. No part of the MRISAFETY.COM web site may be reproduced, stored in any retrieval system, or transmitted in any form or by any means, physical, electronic or otherwise, without the prior written permission of Shellock R & D Services, Inc. or Frank G. Shellock, Ph. D. Request for permission to reproduce any information contained on the MRISAFETY.COM web site should be addressed to: frank.shellock@gte.net
Be sure to read our Disclaimer.