Search THE LIST.   All parameters below are optional.  Click Search button.



     ALL (default) means search results will contain *ALL* words you type above.
                       Selecting ANY returns records having *ANY* words above. (more recs returned) 
   Result Status
Clear Search Fields Click Here for the Info and Terminology Page Regarding THE LIST    
Records: 4581                              Click Here for Search HELP  
Per page:   First Prev   1 2 3 4 5 6 7 8 9 10 of  153  Next Last                                    
Object Status Ascending Strength Reference Safety Info
Intrauterine contraceptive device (IUD), Copper T (copper)
Searle Pharmaceuticals
Chicago, IL 
 Safe

1.5 

54. Mark AS, Hricak H. Intrauterine contraceptive devices: MR imaging. Radiology 1987;162:311-314.  Intrauterine Contraceptive Devices (IUDs) and Other Contraceptive Devices 
Intrauterine Contraceptive Device (IUD)
Lippey Loop, Plastic 
 Safe

1.5, 3 

  Intrauterine Contraceptive Devices (IUDs) and Other Contraceptive Devices 
Intima-II I.V. Catheter System
misc.
BD Medical Systems
Becton Dickinson
Sandy, Utah 
 Safe

1.5 

  Miscellaneous Implants and Devices 
Langenbeck Periosteal Elevator
(304 SS)
misc.
Johnson & Johnson Professional, Inc.
Raynham, MA 
 Safe

1.5 

62. Shellock FG. MRI safety of instruments designed for interventional MRI: assessment of ferromagnetism, heating, and artifacts. Workshop on New Insights into Safety and Compatibility Issues Affecting In Vivo MR, Syllabus, 1998;pp. 39.  Miscellaneous Implants and Devices 
Laparoscopic Graspers
misc.
Greatbatch Scientific
Clarence, NY 
 Safe

1.5 

  Miscellaneous Implants and Devices 
Large Flexible Burr Hole Cover
neurosurgery fixation
C.P. titanium
misc.
Johnson and Johnson
Berkshire, UK 
 Safe

1.5 

  Miscellaneous Implants and Devices 
Large Rigid Burr Hole Cover
neurosurgery fixation
C.P. titanium
misc.
Johnson and Johnson
Berkshire, UK 
 Safe

1.5 

  Miscellaneous Implants and Devices 
Scalpel, Microsharp Ceramic Scalpels,
sizes #10, #11, #11c, #15 (ceramic)
misc.
MicroSurgical Techniques, Inc.
Fort Collins, CO 
 Safe

1.5 

48. Shellock FG, Shellock VJ. Evaluation of MR compatibility of 38 bioimplants and devices. Radiology 1995;197:174.  Surgical Instruments and Devices 
Shunt valve, Holter-Hausner type
misc.
Holter-Hausner, Inc.
Bridgeport, PA 
 Safe

1.5 

55. Go KG, Kamman RL, Mooyaart EL. Interaction of metallic neurosurgical implants with magnetic resonance imaging at 1.5 Tesla as a cause of image distortion and of hazardous movement of the implant. Clin Neurosurg 1989;91:109-115.  Cerebrospinal Fluid (CSF) Shunt Valves and Accessories 
Sponge Forcep
(Ti6Al-4V)
misc.
Johnson & Johnson Professional, Inc.
Raynham, MA 
 Safe

1.5 

62. Shellock FG. MRI safety of instruments designed for interventional MRI: assessment of ferromagnetism, heating, and artifacts. Workshop on New Insights into Safety and Compatibility Issues Affecting In Vivo MR, Syllabus, 1998;pp. 39.  Miscellaneous Implants and Devices 
Stereotactic headframe with removable mouthpiece
(aluminum, 8-18 SS Delrin, titanium)
misc.
Compass International, Inc.
Rochester, MN 
 Safe

1.5 

  Miscellaneous Implants and Devices 
Suction/Irrigation Handle for Sinuscope
misc.
Greatbatch Scientific
Clarence, NY 
 Safe

1.5, 3 

  Miscellaneous Implants and Devices 
Winged infusion set
MRI compatible
misc.
E-Z-EM, Inc.
Westbury, NY 
 Safe

1.5 

58. To SYC, Lufkin RB, Chiu L. MR-compatible winged infusion set. Comput Med Imag Graph 1989;13:469-472.  Miscellaneous Implants and Devices 
Woodson Elevator
(304 SS)
misc.
Johnson & Johnson Professional, Inc.
Raynham, MA 
 Safe

1.5 

62. Shellock FG. MRI safety of instruments designed for interventional MRI: assessment of ferromagnetism, heating, and artifacts. Workshop on New Insights into Safety and Compatibility Issues Affecting In Vivo MR, Syllabus, 1998;pp. 39.  Miscellaneous Implants and Devices 
Clip 250, double tantalum clip (tantalum)
ocular
Mira Inc. 
 Safe

1.5 

29. Shellock FG, Myers SM, Schatz CJ. Ex vivo evaluation of ferromagnetism determined for metallic scleral "buckles" exposed to a 1.5 T MR scanner. Radiology 1992;185:288-289.  Ocular Implants, Lens Implants, and Devices 
Clip 50, double tantalum clip (tantalum)
ocular
Mira Inc. 
 Safe

1.5 

29. Shellock FG, Myers SM, Schatz CJ. Ex vivo evaluation of ferromagnetism determined for metallic scleral "buckles" exposed to a 1.5 T MR scanner. Radiology 1992;185:288-289.  Ocular Implants, Lens Implants, and Devices 
Clip 51, single tantalum clip (tantalum)
ocular
Mira Inc. 
 Safe

1.5 

29. Shellock FG, Myers SM, Schatz CJ. Ex vivo evaluation of ferromagnetism determined for metallic scleral "buckles" exposed to a 1.5 T MR scanner. Radiology 1992;185:288-289.  Ocular Implants, Lens Implants, and Devices 
Clip 52, single tantalum clip (tantalum)
ocular
Mira Inc. 
 Safe

1.5 

29. Shellock FG, Myers SM, Schatz CJ. Ex vivo evaluation of ferromagnetism determined for metallic scleral "buckles" exposed to a 1.5 T MR scanner. Radiology 1992;185:288-289.  Ocular Implants, Lens Implants, and Devices 
Double tantalum clip (tantalum)
ocular
Storz Instrument Co. 
 Safe

1.5 

29. Shellock FG, Myers SM, Schatz CJ. Ex vivo evaluation of ferromagnetism determined for metallic scleral "buckles" exposed to a 1.5 T MR scanner. Radiology 1992;185:288-289.  Ocular Implants, Lens Implants, and Devices 
Double tantalum clip style 250 (tantalum)
ocular
Storz Instrument Co. 
 Safe

1.5 

29. Shellock FG, Myers SM, Schatz CJ. Ex vivo evaluation of ferromagnetism determined for metallic scleral "buckles" exposed to a 1.5 T MR scanner. Radiology 1992;185:288-289.  Ocular Implants, Lens Implants, and Devices 
Gold eyelid spring
ocular 
 Safe

1.5 

  Ocular Implants, Lens Implants, and Devices 
Intraocular lens implant
Binkhorst, iridocapsular lense
platinum-iridium loop (platinum, iridium)
ocular 
 Safe

1.0 

31. Albert DW, Olson KR, Parel JM, et al. Magnetic resonance imaging and retinal tacks. Arch Ophthalmol 1990;108:320-321.  Ocular Implants, Lens Implants, and Devices 
Intraocular lens implant
Binkhorst, iridocapsular lense
platinum-iridium loop
ocular 
 Safe

1.5 

31. Albert DW, Olson KR, Parel JM, et al. Magnetic resonance imaging and retinal tacks. Arch Ophthalmol 1990;108:320-321.  Ocular Implants, Lens Implants, and Devices 
Intraocular lens implant
Binkhorst, iridocapsular lense
titanium loop (titanium)
ocular 
 Safe

1.0 

31. Albert DW, Olson KR, Parel JM, et al. Magnetic resonance imaging and retinal tacks. Arch Ophthalmol 1990;108:320-321.  Ocular Implants, Lens Implants, and Devices 
Intraocular lens implant
Worst, platinum clip lense
ocular 
 Safe

1.0 

31. Albert DW, Olson KR, Parel JM, et al. Magnetic resonance imaging and retinal tacks. Arch Ophthalmol 1990;108:320-321.  Ocular Implants, Lens Implants, and Devices 
Retinal tack (303 SS)
ocular
Bascom Palmer Eye Institute 
 Safe

1.5 

32. Joondeph BC, Peyman GA, Mafee MF, et al. Magnetic resonance imaging and retinal tacks [Letter]. Arch Ophthalmol 1987;105:1479-1480.  Ocular Implants, Lens Implants, and Devices 
Retinal tack (303 SS)
ocular
Duke 
 Safe

1.5 

32. Joondeph BC, Peyman GA, Mafee MF, et al. Magnetic resonance imaging and retinal tacks [Letter]. Arch Ophthalmol 1987;105:1479-1480.  Ocular Implants, Lens Implants, and Devices 
Retinal tack (aluminum textraoxide)
ocular
Ruby 
 Safe

1.5 

32. Joondeph BC, Peyman GA, Mafee MF, et al. Magnetic resonance imaging and retinal tacks [Letter]. Arch Ophthalmol 1987;105:1479-1480.  Ocular Implants, Lens Implants, and Devices 
Retinal tack (cobalt, nickel)
ocular
Greishaber
Fallsington, PA 
 Safe

1.5 

32. Joondeph BC, Peyman GA, Mafee MF, et al. Magnetic resonance imaging and retinal tacks [Letter]. Arch Ophthalmol 1987;105:1479-1480.  Ocular Implants, Lens Implants, and Devices 
Cannulated cancellous screw
6.5 x 50 mm (titanium alloy)
orthopedic implant
DePuy ACE Medical Co.
El Segundo, CA 
 Safe

1.5 

  Orthopedic Implants, Materials, and Devices 

_____________________________________________________________________________________
  (c) 2017 by Shellock R & D Services, Inc. and Frank G. Shellock, Ph.D. All Rights Reserved. All copyrights and pertinent trademarks are owned by Shellock R & D Services, Inc. and Frank G. Shellock, Ph.D. No part of the MRISAFETY.COM web site may be reproduced, stored in any retrieval system, or transmitted in any form or by any means, physical, electronic or otherwise, without the prior written permission of Shellock R & D Services, Inc. or Frank G. Shellock, Ph. D. Request for permission to reproduce any information contained on the MRISAFETY.COM web site should be addressed to: frank.shellock@gte.net
Be sure to read our Disclaimer.