Default.asp?T_MRI_DOC_LISTOrder=Sorter_list_status&T_MRI_DOC_LISTDir=ASC&T_MRI_DOC_LISTPage=2
 mri_brain_scan
 Default.asp
 GenPg.asp?pgname=Disclaimer
 TheList_search.asp
 SafetyInfog.asp
 GenPg.asp?pgname=ScreeningForm
 GenPg.asp?pgname=ProductTesting
 GenPg.asp?pgname=OrderingBooks
 GenPg.asp?pgname=Lectures
 GenPg.asp?pgname=AboutDrShellock
 PriorityEmail.asp
 
 mri_brain_scan
 

Search THE LIST.   All parameters below are optional.  Click Search button.



     ALL (default) means search results will contain *ALL* words you type above.
                       Selecting ANY returns records having *ANY* words above. (more recs returned) 
   Result Status
Clear Search Fields Click Here for the Info and Terminology Page Regarding THE LIST    
Records: 4581                              Click Here for Search HELP  
Per page:   First Prev   1 2 3 4 5 6 7 8 9 10 of  153  Next Last                                    
Object Status Ascending Strength Reference Safety Info
Premium SurgiClip, S-9
C.P. titanium
hemostatic clip
United States Surgical Corp.
Norwalk, CT 
 Safe

1.5 

71. DeLacure MD, Wang HZ. Magnetic resonance imaging assessment of microvascular anastomotic device for ferromagnetism. J Reconstr Microsurg 1997;13:571-574.  Hemostatic Clips, Other Clips, Fasteners, and Staples 
Surgiclip, M-9.5
C.P. titanium
hemostatic clip
United States Surgical Corp.
Norwalk, CT 
 Safe

1.5 

71. DeLacure MD, Wang HZ. Magnetic resonance imaging assessment of microvascular anastomotic device for ferromagnetism. J Reconstr Microsurg 1997;13:571-574.  Hemostatic Clips, Other Clips, Fasteners, and Staples 
Surgiclip, M-11
C.P. titanium
hemostatic clip
United States Surgical Corp.
Norwalk, CT 
 Safe

1.5 

71. DeLacure MD, Wang HZ. Magnetic resonance imaging assessment of microvascular anastomotic device for ferromagnetism. J Reconstr Microsurg 1997;13:571-574.  Hemostatic Clips, Other Clips, Fasteners, and Staples 
Surgiclip, Auto Suture M-9.5 (SS)
hemostatic clip
United States Surgical Corp.
Norwalk, CT 
 Safe

1.5 

3. Shellock FG, Crues JV. High-field strength MR imaging and metallic biomedical implants: an ex vivo evaluation of deflection forces. Am J Roentgenol 1988;151:389-392.  Hemostatic Clips, Other Clips, Fasteners, and Staples 
Mitral Prosthetic Heart Valve
Model 2100, heart valve
TRI Technologies
Brazil 
 Safe

1.5 

70. Shellock FG, Shellock VJ. MRI Safety of cardiovascular implants: evaluation of ferromagnetism, heating, and artifacts. Radiology 2000;214:P19H.  Heart Valves and Annuloplasty Rings 
Mitroflow
Aortic, Model 11A
Delrin
heart valve
Mitroflow Sulzer CarboMedics
U.K. 
 Safe

1.5 

75. Edwards, M-B, Taylor KM, Shellock FG. Prosthetic heart valves: evaluation of magnetic field interactions, heating, and artifacts at 1.5 Tesla. J Magn Reson Imag 2000;12:363-369.  Heart Valves and Annuloplasty Rings 
Mitroflow
Aortic, Model 14A
Delrin
heart valve
Mitroflow Sulzer CarboMedics
U.K. 
 Safe

1.5 

75. Edwards, M-B, Taylor KM, Shellock FG. Prosthetic heart valves: evaluation of magnetic field interactions, heating, and artifacts at 1.5 Tesla. J Magn Reson Imag 2000;12:363-369.  Heart Valves and Annuloplasty Rings 
Mitroflow
Mitral, Model 11M
Delrin
heart valve
Mitroflow Sulzer CarboMedics
U.K. 
 Safe

1.5 

75. Edwards, M-B, Taylor KM, Shellock FG. Prosthetic heart valves: evaluation of magnetic field interactions, heating, and artifacts at 1.5 Tesla. J Magn Reson Imag 2000;12:363-369.  Heart Valves and Annuloplasty Rings 
Mitroflow Pericardial Heart Valve
Model 12, heart valve
Sulzer-Medica and Mitroflow International
Richmond, B.C.
Canada 
 Safe

1.5 

70. Shellock FG, Shellock VJ. MRI Safety of cardiovascular implants: evaluation of ferromagnetism, heating, and artifacts. Radiology 2000;214:P19H.  Heart Valves and Annuloplasty Rings 
Adson Tissue Forcep
(Ti6Al-4V)
misc.
Johnson & Johnson
Professional, Inc.
Raynham, MA 
 Safe

1.5 

62. Shellock FG. MRI safety of instruments designed for interventional MRI: assessment of ferromagnetism, heating, and artifacts. Workshop on New Insights into Safety and Compatibility Issues Affecting In Vivo MR, Syllabus, 1998;pp. 39.  Surgical Instruments and Devices 
AMS Artificial Bowel Sphincter Prosthesis
misc.
American Medical Systems
Minnetonka, MN 
 Safe

1.5 

  Miscellaneous Implants and Devices 
AMS Artificial Urinary Sphincter 791
misc.
American Medical Systems
Minnetonka, MN 
 Safe

1.5 

  Miscellaneous Implants and Devices 
AMS Mainstay Soft-Tissue Anchor
misc.
American Medical Systems
Minnetonka, MN 
 Safe

1.5 

  Miscellaneous Implants and Devices 
Artificial urinary sphincter
AMS 800
misc.
American Medical Systems, American Medical Systems Inc., www.americanmedicalsystems.com  
 Safe

1.5 

3. Shellock FG, Crues JV. High-field strength MR imaging and metallic biomedical implants: an ex vivo evaluation of deflection forces. Am J Roentgenol 1988;151:389-392.  Miscellaneous Implants and Devices 
B-D PosiFlow
needleless IV access connector
misc.
Becton Dickinson
Sandy, Utah 
 Safe

1.5 

  Miscellaneous Implants and Devices 
BioClip
neurosurgery fixation
misc.
Codman
Johnson and Johnson
Berkshire, UK 
 Safe

1.5 

  Miscellaneous Implants and Devices 
BioMesh
neurosurgery fixation
C.P. titanium
misc.
Johnson and Johnson
Berkshire, UK 
 Safe

1.5 

  Miscellaneous Implants and Devices 
Biosearch endo-feeding tube
misc. 
 Safe

1.5 

  Miscellaneous Implants and Devices 
Burr Hole Cover
neurosurgery fixation
C.P. titanium
misc.
Johnson and Johnson
Berkshire, UK 
 Safe

1.5 

  Miscellaneous Implants and Devices 
Cerebral ventricular shunt tube connector,
Accu-flow right angle
misc.
Codman
Randolf, MA 
 Safe

1.5, 3 

94. Codman, a Johnson and Johnson Company, Raynham, MA; Cerebrospinal Fluid Shunt Valves and Accessories, http://www.depuysynthes.com/  Cerebrospinal Fluid (CSF) Shunt Valves and Accessories 
Cerebral ventricular shunt tube connector,
Accu-Flow, straight
misc.
Codman
Randolf, MA 
 Safe

1.5 

3. Shellock FG, Crues JV. High-field strength MR imaging and metallic biomedical implants: an ex vivo evaluation of deflection forces. Am J Roentgenol 1988;151:389-392.  Cerebrospinal Fluid (CSF) Shunt Valves and Accessories 
Cerebral ventricular shunt tube connector,
Accu-flow, T-connector
misc.
Codman
Randolf, MA 
 Safe

1.5 

3. Shellock FG, Crues JV. High-field strength MR imaging and metallic biomedical implants: an ex vivo evaluation of deflection forces. Am J Roentgenol 1988;151:389-392.  Cerebrospinal Fluid (CSF) Shunt Valves and Accessories 
Sulzer/Carbomedics Synergy PC
Pericardial Heart Valve
Sulzer-Medica and Mitroflow International
Richmond, B.C.
Canada 
 Safe

1.5 

70. Shellock FG, Shellock VJ. MRI Safety of cardiovascular implants: evaluation of ferromagnetism, heating, and artifacts. Radiology 2000;214:P19H.  Heart Valves and Annuloplasty Rings 
Tascon
Aortic
Elgiloy

heart valve
Medtronic Inc.
Minneapolis, MN 
 Safe

1.5 

75. Edwards, M-B, Taylor KM, Shellock FG. Prosthetic heart valves: evaluation of magnetic field interactions, heating, and artifacts at 1.5 Tesla. J Magn Reson Imag 2000;12:363-369.  Heart Valves and Annuloplasty Rings 
Contraceptive diaphragm
Gyne T
misc. 
 Safe

1.5 

47. Hess T, Stepanow B, Knopp MV. Safety of intrauterine contraceptive devices during MR imaging. Eur Radiol 1996;6:66-68.  Miscellaneous Implants and Devices 
Contraceptive IUD
Multiload Cu375 (copper, silver) 
 Safe

1.5 

47. Hess T, Stepanow B, Knopp MV. Safety of intrauterine contraceptive devices during MR imaging. Eur Radiol 1996;6:66-68.  Intrauterine Contraceptive Devices (IUDs) and Other Contraceptive Devices 
Contraceptive IUD
Nova T (copper, silver) 
 Safe

1.5 

47. Hess T, Stepanow B, Knopp MV. Safety of intrauterine contraceptive devices during MR imaging. Eur Radiol 1996;6:66-68.  Intrauterine Contraceptive Devices (IUDs) and Other Contraceptive Devices 
Cranial Ceramic Drill bit (ceramic)
misc.
MicroSurgical Techniques Inc.
Fort Collins, CO 
 Safe

1.5 

48. Shellock FG, Shellock VJ. Evaluation of MR compatibility of 38 bioimplants and devices. Radiology 1995;197:174.  Miscellaneous Implants and Devices 
Craniofix, bone flap fixation system (titanium alloy)
misc.
Aesculap, Inc.
South San Francisco, CA 
 Safe

1.5 

50. Shellock FG, Shellock VJ. Evaluation of cranial flap fixation clamps for compatibility with MR imaging. Radiology 1998; 822-825.  Miscellaneous Implants and Devices 
Cranial Screw
neurosurgery fixation
size, 1.5 x 4.5 mm
titanium alloy
misc.
Johnson and Johnson
Berkshire, UK 
 Safe

1.5 

  Miscellaneous Implants and Devices 

_____________________________________________________________________________________
  (c) 2017 by Shellock R & D Services, Inc. and Frank G. Shellock, Ph.D. All Rights Reserved. All copyrights and pertinent trademarks are owned by Shellock R & D Services, Inc. and Frank G. Shellock, Ph.D. No part of the MRISAFETY.COM web site may be reproduced, stored in any retrieval system, or transmitted in any form or by any means, physical, electronic or otherwise, without the prior written permission of Shellock R & D Services, Inc. or Frank G. Shellock, Ph. D. Request for permission to reproduce any information contained on the MRISAFETY.COM web site should be addressed to: frank.shellock@gte.net